DECODE EMU devices represent series of measuring devices for measurement of AC and DC voltages and currents with integrated RS-485 Modbus connection.

There are three different device options supported where the third one, with analogue input unit, offer several subtypes.

  • EMU V3 – for AC voltages measurement 3 x 230V AC
  • EMU C3 – for AC currents measurement (current transformers) 3 x CT 5A AC
  • EMU A3-TTT – 3 x analogue input measurement (TTT designates input type, example: device EMU A3001 features first two inputs 0/4-20mA where the third one features PT100 input)

WIRING DIAGRAM

Jumpers KS1 and KS2 are to be placed only if RS-485 line termination is required. For short distances the termination is not needed. Distances longer than 100m, as well as presence of notable disturbances, require line termination at one of slave devices, specifically the one positioned at the end of line.

TECHNICAL SPECIFICATION

Decode EMU measuring devices
EMU A3
Type T=0
EMU A3
Type T=1
EMU A3
Type T=2
EMU A3
Type T=3
EMU A3
Type T=4
Measured parameters
0-20mA, 4-20mA input resistance 40 Ω
PT 100
PT 1000
0-5V DC
0-10V DC
Measurement range
0-25mA DC
from -50 ⁰C to +150 ⁰C
from -50 ⁰C to +150 C
0-5V DC
0-10V DC
Resolution
0.01mA
0.1 ⁰C
0.1 ⁰C
1mV
1mV
Decode EMU measuring devices
EMU V3
EMU C3
Measured parameters
L1, L2, L3, L12, L23, L31, frequency
CT1, CT2, CT3
Measurement range
0-250V AC rms
0-5A AC rms
Resolution
10mV rms
1mA rms
Measurement type
True RMS
True RMS

TECHNICAL SPECIFICATION

Decode EMU measuring devices
EMU A3 – Type T=0
Measured parameters
0-20mA, 4-20mA input resistance 40 Ω
Measurement range
0-25mA DC
Resolution
0.01mA
Decode EMU measuring devices
EMU A3 – Type T=1
Measured parameters
PT 100
Measurement range
from -50 ⁰C to +150 ⁰C
Resolution
0.1 ⁰C
Decode EMU measuring devices
EMU A3 – Type T=2
Measured parameters
PT 1000
Measurement range
from -50 ⁰C to +150 C
Resolution
0.1 ⁰C
Decode EMU measuring devices
EMU A3 – Type T=3
Measured parameters
0-5V DC
Measurement range
0-5V DC
Resolution
1mV
Decode EMU measuring devices
EMU A3 – Type T=4
Measured parameters
0-10V DC
Measurement range
0-10V DC
Resolution
0.01mA 1mV
Decode EMU measuring devices
EMU V3
Measured parameters
L1, L2, L3, L12, L23, L31, frequency
Measurement range
0-250V AC rms
Resolution
10mV rms
Measurement type
True RMS
Decode EMU measuring devices
EMU C3
Measured parameters
CT1, CT2, CT3
Measurement range
0-5A AC rms
Resolution
1mA rms
Measurement type
True RMS

ORDERING INFORMATIONS

Model

SKU

Description

Price

EMU A3

10273

3 x analogue input measurement (TTT designates input type, example: device EMU A3001 features first two inputs 0/4-20mA where the third one features PT100 input)

85.00

EMU V3

10271

AC voltages measurement 3 x 230V AC

85.00

EMU C3

10272

AC currents measurement (current transformers) 3 x CT 5A AC

85.00

ORDERING INFORMATIONS

EMU A3

3 x analogue input measurement (TTT designates input type, example: device EMU A3001 features first two inputs 0/4-20mA where the third one features PT100 input)

85.00

EMU V3

AC voltages measurement 3 x 230V AC

85.00

EMU C3

AC currents measurement (current transformers) 3 x CT 5A AC

85.00

ORDERING INFORMATIONS

EMU A3

3 x analogue input measurement (TTT designates input type, example: device EMU A3001 features first two inputs 0/4-20mA where the third one features PT100 input)

85.00

EMU V3

AC voltages measurement 3 x 230V AC

85.00

EMU C3

AC currents measurement (current transformers) 3 x CT 5A AC

85.00

PRODUCT DOCUMENTS

TitleCategoriesFile TypeFile SizeLinkhf:doc_categorieshf:file_type
EMU Datasheetpdf238 KBdatasheetpdf
EMU User Manualpdf324 KBuser-manualpdf

YOU MIGHT ALSO NEED